{"id":706,"date":"2024-04-25T08:42:57","date_gmt":"2024-04-25T08:42:57","guid":{"rendered":"https:\/\/denasmash.com\/?page_id=706"},"modified":"2024-12-31T09:21:51","modified_gmt":"2024-12-31T07:21:51","slug":"solid-fuel-boilers-with-capacity-of-250-kw","status":"publish","type":"page","link":"https:\/\/denasmash.com\/en\/boilers\/industrial-water-heating-boilers-from-98-kw-to-2-mw\/solid-fuel-boilers-with-capacity-of-250-kw\/","title":{"rendered":"Solid fuel boilers with a capacity of 250 kW (KW 0.25M)"},"content":{"rendered":"\n<p>A solid fuel boilers with a capacity of KVT-0.25M, designed for heating and hot water heating of residential, administrative and industrial premises with an area of \u200b\u200b1100 to 2750 m\u00b2. Effective, economical, completely safe, the <a href=\"\/en\/boilers\/\" target=\"_blank\" rel=\"noreferrer noopener\">boiler<\/a> is absolutely undemanding in maintenance.<\/p>\n\n\n\n<p>An absolute advantage of the 0.25 KVT boiler is efficient, uninterrupted operation. There is no need to stop the boiler to clean the heat exchanger &#8211; with the help of mechanical turbulators, this procedure is quite simple and reliable. Removal of ash from the furnace occurs automatically with the help of an auger.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">SOLID FUEL BOILERS &#8211; FEATURES OF CONSTRUCTION<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>The KVT-0.25M boiler is designed for almost any solid fuel, it is not tied to a certain type of raw material.<\/li>\n\n\n\n<li>This model has a device for mechanical cleaning of the surface of the heat exchanger from soot. This means that the heat exchanger will work with maximum heat output throughout the heating season.<\/li>\n\n\n\n<li>In the KVT-0.25M model, ash is removed from the furnace automatically with the help of an auger.<\/li>\n\n\n\n<li>The control controller regulates the fuel supply and ensures continuous operation of the boiler in the specified power range. This way you get performance with economical fuel consumption.<\/li>\n\n\n\n<li>Boiler KVT-0.25M only with automatic fuel supply.<\/li>\n\n\n\n<li>A security group and a fire extinguishing system are provided.<\/li>\n\n\n\n<li>Environmental friendliness and safety of the equipment, the level of emission of CO2 into the atmosphere is minimal. The boilers are certified, manufactured in compliance with all norms of current legislation and technical specifications.<\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\">KIT<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Automatic burner.<\/li>\n\n\n\n<li>Mechanical system for cleaning soot from the heat exchanger<\/li>\n\n\n\n<li>Blow fan<\/li>\n\n\n\n<li>Turbulizers<\/li>\n\n\n\n<li>Automatic ash removal system<\/li>\n\n\n\n<li>Waste hopper with fuel supply system to the boiler<\/li>\n\n\n\n<li>Management controller<\/li>\n<\/ol>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\" rowspan=\"2\">Parameters<\/td><td class=\"has-text-align-center\" data-align=\"center\" rowspan=\"2\">Unit measurement<\/td><td class=\"has-text-align-center\" data-align=\"center\">KVT<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">0,25\u041c<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Nominal heat capacity<\/td><td class=\"has-text-align-center\" data-align=\"center\">kW<\/td><td class=\"has-text-align-center\" data-align=\"center\">250<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Area of \u200b\u200bheated premises<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u043c\u00b2<\/td><td class=\"has-text-align-center\" data-align=\"center\">1100-2750<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Range of power adjustments<\/td><td class=\"has-text-align-center\" data-align=\"center\">kW<\/td><td class=\"has-text-align-center\" data-align=\"center\">110-275<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Boiler outlet water temperature<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u00b0C<\/td><td class=\"has-text-align-center\" data-align=\"center\">No more 95<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Working water pressure<\/td><td class=\"has-text-align-center\" data-align=\"center\">MPa<\/td><td class=\"has-text-align-center\" data-align=\"center\">0,4<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">The volume of the coolant<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u043c\u00b3<\/td><td class=\"has-text-align-center\" data-align=\"center\">1,4<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">The temperature of the outgoing gases<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u00b0\u0421<\/td><td class=\"has-text-align-center\" data-align=\"center\">160<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Boiler weight<\/td><td class=\"has-text-align-center\" data-align=\"center\">kg<\/td><td class=\"has-text-align-center\" data-align=\"center\">2650<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" rowspan=\"3\">Overall dimensions (without hopper):<\/td><td class=\"has-text-align-center\" data-align=\"center\">length<\/td><td class=\"has-text-align-center\" data-align=\"center\" rowspan=\"3\">mm<\/td><td class=\"has-text-align-center\" data-align=\"center\">2640<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">width<\/td><td class=\"has-text-align-center\" data-align=\"center\">2192<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">height<\/td><td class=\"has-text-align-center\" data-align=\"center\">2009<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" rowspan=\"3\">Connection size<\/td><td class=\"has-text-align-center\" data-align=\"center\">coolant<\/td><td class=\"has-text-align-center\" data-align=\"center\">&#8211;<\/td><td class=\"has-text-align-center\" data-align=\"center\">Dn 80<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">nipple<\/td><td class=\"has-text-align-center\" data-align=\"center\">PSK<\/td><td class=\"has-text-align-center\" data-align=\"center\">Dn 50<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">funnel<\/td><td class=\"has-text-align-center\" data-align=\"center\">mm<\/td><td class=\"has-text-align-center\" data-align=\"center\">\u00f8296<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" rowspan=\"2\">Efficiency<\/td><td class=\"has-text-align-center\" data-align=\"center\">On pellets<\/td><td class=\"has-text-align-center\" data-align=\"center\" rowspan=\"2\">%<\/td><td class=\"has-text-align-center\" data-align=\"center\">85<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Firewood and its waste (W\u226450%)<\/td><td class=\"has-text-align-center\" data-align=\"center\">&#8211;<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" rowspan=\"2\">Fuel consumption<\/td><td class=\"has-text-align-center\" data-align=\"center\">On pellets<\/td><td class=\"has-text-align-center\" data-align=\"center\" rowspan=\"2\">kg\/hour<\/td><td class=\"has-text-align-center\" data-align=\"center\">57<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">On firewood<\/td><td class=\"has-text-align-center\" data-align=\"center\">&#8211;<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\" colspan=\"2\">Network voltage<\/td><td class=\"has-text-align-center\" data-align=\"center\">V<\/td><td class=\"has-text-align-center\" data-align=\"center\">380 (50Gz)<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"has-text-align-right\">Follow us on\u00a0<a href=\"https:\/\/www.instagram.com\/denasmash.com_pl\/\" target=\"_blank\" rel=\"noreferrer noopener\">Instagram<\/a>\u00a0and\u00a0<a href=\"https:\/\/www.facebook.com\/profile.php?id=100091658104666\" target=\"_blank\" rel=\"noreferrer noopener nofollow\">Facebook<\/a>.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>A solid fuel water heating boiler with a capacity of 250 kW, with a vertical heat exchanger and turbulators, is intended for water heating and hot water heating of residential, administrative and industrial premises with an area of \u200b\u200b1100 to 2750 m\u00b2.<\/p>\n","protected":false},"author":1,"featured_media":946,"parent":454,"menu_order":2,"comment_status":"closed","ping_status":"closed","template":"product-page.php","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-706","page","type-page","status-publish","has-post-thumbnail","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v26.7 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Solid fuel boilers with a capacity 250 (KW 0.25M) - DENASMASH<\/title>\n<meta name=\"description\" content=\"Solid fuel boilers with a capacity of 250 kW(KW 0.25M) \u26a1 Equipment for the production of pellets \ud83d\udd0b Poltava Mechanical Plant \ud83d\udee0 050 369 11 44\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/denasmash.com\/en\/boilers\/industrial-water-heating-boilers-from-98-kw-to-2-mw\/solid-fuel-boilers-with-capacity-of-250-kw\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Solid fuel boilers with a capacity 250 (KW 0.25M) - DENASMASH\" \/>\n<meta property=\"og:description\" content=\"Solid fuel boilers with a capacity of 250 kW(KW 0.25M) \u26a1 Equipment for the production of pellets \ud83d\udd0b Poltava Mechanical Plant \ud83d\udee0 050 369 11 44\" \/>\n<meta property=\"og:url\" content=\"https:\/\/denasmash.com\/en\/boilers\/industrial-water-heating-boilers-from-98-kw-to-2-mw\/solid-fuel-boilers-with-capacity-of-250-kw\/\" \/>\n<meta property=\"og:site_name\" content=\"&quot;PMZ Denasmash&quot; LLC\" \/>\n<meta property=\"article:modified_time\" content=\"2024-12-31T07:21:51+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/denasmash.com\/en\/wp-content\/uploads\/sites\/2\/2024\/04\/Frame-18-5.png\" \/>\n\t<meta property=\"og:image:width\" content=\"432\" \/>\n\t<meta property=\"og:image:height\" content=\"315\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Solid fuel boilers with a capacity 250 (KW 0.25M) - DENASMASH","description":"Solid fuel boilers with a capacity of 250 kW(KW 0.25M) \u26a1 Equipment for the production of pellets \ud83d\udd0b Poltava Mechanical Plant \ud83d\udee0 050 369 11 44","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/denasmash.com\/en\/boilers\/industrial-water-heating-boilers-from-98-kw-to-2-mw\/solid-fuel-boilers-with-capacity-of-250-kw\/","og_locale":"en_US","og_type":"article","og_title":"Solid fuel boilers with a capacity 250 (KW 0.25M) - DENASMASH","og_description":"Solid fuel boilers with a capacity of 250 kW(KW 0.25M) \u26a1 Equipment for the production of pellets \ud83d\udd0b Poltava Mechanical Plant \ud83d\udee0 050 369 11 44","og_url":"https:\/\/denasmash.com\/en\/boilers\/industrial-water-heating-boilers-from-98-kw-to-2-mw\/solid-fuel-boilers-with-capacity-of-250-kw\/","og_site_name":"&quot;PMZ Denasmash&quot; LLC","article_modified_time":"2024-12-31T07:21:51+00:00","og_image":[{"width":432,"height":315,"url":"https:\/\/denasmash.com\/en\/wp-content\/uploads\/sites\/2\/2024\/04\/Frame-18-5.png","type":"image\/png"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/denasmash.com\/en\/boilers\/industrial-water-heating-boilers-from-98-kw-to-2-mw\/solid-fuel-boilers-with-capacity-of-250-kw\/","url":"https:\/\/denasmash.com\/en\/boilers\/industrial-water-heating-boilers-from-98-kw-to-2-mw\/solid-fuel-boilers-with-capacity-of-250-kw\/","name":"Solid fuel boilers with a capacity 250 (KW 0.25M) - DENASMASH","isPartOf":{"@id":"https:\/\/denasmash.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/denasmash.com\/en\/boilers\/industrial-water-heating-boilers-from-98-kw-to-2-mw\/solid-fuel-boilers-with-capacity-of-250-kw\/#primaryimage"},"image":{"@id":"https:\/\/denasmash.com\/en\/boilers\/industrial-water-heating-boilers-from-98-kw-to-2-mw\/solid-fuel-boilers-with-capacity-of-250-kw\/#primaryimage"},"thumbnailUrl":"https:\/\/denasmash.com\/en\/wp-content\/uploads\/sites\/2\/2024\/04\/Frame-18-5.png","datePublished":"2024-04-25T08:42:57+00:00","dateModified":"2024-12-31T07:21:51+00:00","description":"Solid fuel boilers with a capacity of 250 kW(KW 0.25M) \u26a1 Equipment for the production of pellets \ud83d\udd0b Poltava Mechanical Plant \ud83d\udee0 050 369 11 44","breadcrumb":{"@id":"https:\/\/denasmash.com\/en\/boilers\/industrial-water-heating-boilers-from-98-kw-to-2-mw\/solid-fuel-boilers-with-capacity-of-250-kw\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/denasmash.com\/en\/boilers\/industrial-water-heating-boilers-from-98-kw-to-2-mw\/solid-fuel-boilers-with-capacity-of-250-kw\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/denasmash.com\/en\/boilers\/industrial-water-heating-boilers-from-98-kw-to-2-mw\/solid-fuel-boilers-with-capacity-of-250-kw\/#primaryimage","url":"https:\/\/denasmash.com\/en\/wp-content\/uploads\/sites\/2\/2024\/04\/Frame-18-5.png","contentUrl":"https:\/\/denasmash.com\/en\/wp-content\/uploads\/sites\/2\/2024\/04\/Frame-18-5.png","width":432,"height":315,"caption":"Boilers with a capacity of 250 kW - DENASMASH"},{"@type":"BreadcrumbList","@id":"https:\/\/denasmash.com\/en\/boilers\/industrial-water-heating-boilers-from-98-kw-to-2-mw\/solid-fuel-boilers-with-capacity-of-250-kw\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Main","item":"https:\/\/denasmash.com\/en\/"},{"@type":"ListItem","position":2,"name":"Solid fuel boilers","item":"https:\/\/denasmash.com\/en\/boilers\/"},{"@type":"ListItem","position":3,"name":"Industrial water heating boilers from 98 kW to 2 MW","item":"https:\/\/denasmash.com\/en\/boilers\/industrial-water-heating-boilers-from-98-kw-to-2-mw\/"},{"@type":"ListItem","position":4,"name":"Solid fuel boilers with a capacity of 250 kW (KW 0.25M)"}]},{"@type":"WebSite","@id":"https:\/\/denasmash.com\/en\/#website","url":"https:\/\/denasmash.com\/en\/","name":"PMZ Denasmash","description":"","publisher":{"@id":"https:\/\/denasmash.com\/en\/#organization"},"alternateName":"PMZ Denasmash","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/denasmash.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/denasmash.com\/en\/#organization","name":"LLC \"PMZ DENASMASH\"","alternateName":"Limited Liability Company \"PMZ DENASMASH\"","url":"https:\/\/denasmash.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/denasmash.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/denasmash.com\/en\/wp-content\/uploads\/sites\/2\/2024\/05\/Logo.svg","contentUrl":"https:\/\/denasmash.com\/en\/wp-content\/uploads\/sites\/2\/2024\/05\/Logo.svg","caption":"LLC \"PMZ DENASMASH\""},"image":{"@id":"https:\/\/denasmash.com\/en\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/t.me\/+380503691144","https:\/\/wa.me\/+380503691144","https:\/\/www.youtube.com\/channel\/UCwVHLI2BVCiiu5uP47uSDbg"]}]}},"_links":{"self":[{"href":"https:\/\/denasmash.com\/en\/wp-json\/wp\/v2\/pages\/706","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/denasmash.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/denasmash.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/denasmash.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/denasmash.com\/en\/wp-json\/wp\/v2\/comments?post=706"}],"version-history":[{"count":4,"href":"https:\/\/denasmash.com\/en\/wp-json\/wp\/v2\/pages\/706\/revisions"}],"predecessor-version":[{"id":1953,"href":"https:\/\/denasmash.com\/en\/wp-json\/wp\/v2\/pages\/706\/revisions\/1953"}],"up":[{"embeddable":true,"href":"https:\/\/denasmash.com\/en\/wp-json\/wp\/v2\/pages\/454"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/denasmash.com\/en\/wp-json\/wp\/v2\/media\/946"}],"wp:attachment":[{"href":"https:\/\/denasmash.com\/en\/wp-json\/wp\/v2\/media?parent=706"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}